髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法)
Multiplex Assay Kit for Myelin Basic Protein (MBP) ,etc. by FLIA (Flow Luminescence Immunoassay)
Myelin A1 protein; Myelin membrane encephalitogenic protein
(注:單次混測多因子不超過8個指標 )
- 編號LMA539Ra
- 物種Rattus norvegicus (Rat,大鼠) 相同的名稱,不同的物種。
- 實驗方法雙抗夾心
- 反應時長3.5h
- 檢測范圍0.01-10ng/mL
- 靈敏度最小可檢測劑量小于等于0.003 ng/mL.
- 樣本類型Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- 下載 英文說明書 中文說明書
- 規(guī)格 8指標數(shù) 7指標數(shù) 6指標數(shù) 5指標數(shù) 4指標數(shù) 3指標數(shù) 2指標數(shù)1指標數(shù)
- 價格 ¥ 2562 ¥ 2660 ¥ 2808 ¥ 3005 ¥ 3202 ¥ 3497 ¥ 3941 計算器 ¥ 4926 添加到價格計算器
- 欲了解實際交易價格和更多情況,請與當?shù)亟?jīng)銷商聯(lián)系!
特異性
本試劑盒用于檢測髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法),經(jīng)檢測與其它相似物質無明顯交叉反應。
由于受到技術及樣本來源的限制,不可能完成對所有相關或相似物質交叉反應檢測,因此本試劑盒有可能與未經(jīng)檢測的其它物質有交叉反應。
回收率
分別于定值血清及血漿樣本中加入一定量的髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法)(加標樣品),重復測定并計算其均值,回收率為測定值與理論值的比率。
樣本 | 回收率范圍(%) | 平均回收率(%) |
serum(n=5) | 92-105 | 99 |
EDTA plasma(n=5) | 91-105 | 99 |
heparin plasma(n=5) | 81-89 | 86 |
精密度
精密度用樣品測定值的變異系數(shù)CV表示。CV(%) = SD/mean×100
批內(nèi)差:取同批次試劑盒對低、中、高值定值樣本進行定量檢測,每份樣本連續(xù)測定20 次,分別計算不同濃度樣本的平均值及SD值。
批間差:選取3個不同批次的試劑盒分別對低、中、高值定值樣本進行定量測定,每個樣本使用同一試劑盒重復測定8次,分別計算不同濃度樣本的平均值及SD值。
批內(nèi)差: CV<10%
批間差: CV<12%
線性
在定值血清及血漿樣本內(nèi)加入適量的髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法),并倍比稀釋成1:2,1:4,1:8,1:16的待測樣本,線性范圍即為稀釋后樣本中髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法)含量的測定值與理論值的比率。
樣本 | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 99-105% | 95-105% | 86-93% | 80-105% |
EDTA plasma(n=5) | 82-94% | 83-91% | 97-105% | 88-96% |
heparin plasma(n=5) | 92-101% | 83-92% | 96-104% | 79-104% |
穩(wěn)定性
經(jīng)測定,試劑盒在有效期內(nèi)按推薦溫度保存,其活性降低率小于5%。
為減小外部因素對試劑盒破壞前后檢測值的影響,實驗室的環(huán)境條件需盡量保持一致,尤其是實驗室內(nèi)溫度、濕度及溫育條件。其次由同一實驗員來進行操作可減少人為誤差。
實驗流程
1. 實驗前標準品、試劑及樣本準備;
2. 加樣(標準品、樣本、磁珠)標準品或樣本100μL及磁珠10μL,
37°C酶標板振蕩器孵育90分鐘;
3. 磁吸甩干,加檢測溶液A100μL,37°C酶標板振蕩器孵育60分鐘;
4. 磁吸洗板3次;
5. 加檢測溶液B100μL,37°C振動孵育30分鐘;
6. 磁吸洗板3次;
7. 加鞘液100μL,旋渦震蕩2分鐘后讀數(shù)。
實驗原理
將髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法)抗體包被于磁珠,制成固相載體,向微孔中分別加入標準品或標本以及磁珠,其中的髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法)與連接于固相載體上的抗體結合,然后加入生物素化的髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法)抗體,將未結合的生物素化抗體洗凈后,加入PE標記的親和素,再次徹底洗滌后即可上機讀數(shù)。MFI值和樣品中的髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法)呈正相關。
贈品
增值服務
相關產(chǎn)品
編號 | 適用物種:Rattus norvegicus (Rat,大鼠) | 應用(僅供研究使用,不用于臨床診斷!) |
RPA539Ra01 | 髓鞘堿性蛋白(MBP)重組蛋白 | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA539Ra01 | 髓鞘堿性蛋白(MBP)多克隆抗體 | WB; IHC; ICC; IP. |
PAA539Ra52 | 髓鞘堿性蛋白(MBP)多克隆抗體 | WB; IHC; ICC; IP. |
MAA539Ra21 | 髓鞘堿性蛋白(MBP)單克隆抗體 | WB; IHC; ICC; IP. |
SEA539Ra | 髓鞘堿性蛋白(MBP)檢測試劑盒(酶聯(lián)免疫吸附試驗法) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA539Ra | 髓鞘堿性蛋白(MBP)檢測試劑盒(酶聯(lián)免疫吸附試驗法) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA539Ra | 髓鞘堿性蛋白(MBP)等多因子檢測試劑盒(流式熒光發(fā)光法) | FLIA Kit for Antigen Detection. |
參考文獻
雜志 | 參考文獻 |
PLOS ONE | CD98 Positive Eosinophils Contribute to T Helper 1 Pattern Inflammation [PlosOne: Source] |
Journal of Occupational Health | Effects of Exposure to 1-Bromopropane on Astrocytes and Oligodendrocytes in Rat Brain [Pubmed: 23183024] |
Pak J Med Sci | Myelin basic protein and ischemia modified albumin levels in acute ischemic stroke cases [PubMed: 26648996] |
Experimental and Toxicologic Pathology | Morphology and staining behavior of neutrophilic and eosinophilic granulocytes of the common marmoset (Callithrix jacchus) [Pubmed:27165445] |
Acta Angiologica | Serum microtubule associated protein tau and myelin basic protein as the potential markers of brain ischaemia-reperfusion injury in patients undergoing carotid endarterectomy [AA.2016.0008] |
Stem Cells. | Myelin Basic Protein Regulates Primitive and Definitive Neural Stem Cell Proliferation from the Adult Spinal Cord. [pubmed:27573615] |
Environmental Science and Pollution Research | Glial?markers?and?emotional?memory?in?rats?following?acute?cerebral?radiofrequency?exposures. [pubmed:27696165] |
Acta Angiol | Serum microtubule associated protein tau and myelin basic protein as the potential markers of brain ischaemia-reperfusion injury in patients undergoing carotid endarterectomy [AA.2016.0008] |
PLoS?Neglected?Tropical?Diseases | Functional and phenotypic evaluation of eosinophils from patients with the acute form of paracoccidioidomycosis [pubmed:28489854] |
Pesticide Biochemistry and Physiology | Acrolein-mediated neurotoxicity in growing Wistar male rats [Pubmed:30033014] |
International Journal of Livestock Research | Association and Risk of Canine Distemper with Respect to Age, Sex and Breed of Dogs Suffering from Demyelinating Neuropathies [10.5455:ijlr.20170811080455] |
Microchimica Acta | Biosensors and nanobiosensors for rapid detection of autoimmune diseases: a review [Pubmed: 31760523] |
The role of light desynchronosis in the development of stress-induced aging [] | |
Adv Med Sci | Association of eosinophil-mediated inflammatory biomarkers with the presence of the Schatzki ring [34091432] |
biomolecules | Searching for Noninvasive Predictors of the Diagnosis and Monitoring of Eosinophilic Esophagitis?aThe Importance of Biomarkers of the Inflammatory Reaction??- [] |
Talanta | Monitoring autoimmune diseases by bioelectrochemical detection of autoantibodies. Application to the determination of anti-myelin basic protein autoantibodies in?… [Pubmed:35202838] |